Large Water Meter Testing – Certification Exam 2019
Quiz Summary
0 of 38 Questions completed
Questions:
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- Not categorized 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- 31
- 32
- 33
- 34
- 35
- 36
- 37
- 38
- Current
- Review
- Answered
- Correct
- Incorrect
-
Question 1 of 38
1. Question
True or False: The OMNI V2 Tester has a resettable electronic register.
-
Question 2 of 38
2. Question
How many increments are found on a Sensus direct reading register dial face?
-
Question 3 of 38
3. Question
True or False: To calculate the amount of water registered during a test, you should subtract the start value from the stop value.
-
Question 4 of 38
4. Question
True or False: A slightly curved but mostly straight test hose is necessary at all testing sites.
-
Question 5 of 38
5. Question
Which of the following tests should be performed first at a new test site?
-
Question 6 of 38
6. Question
When you slam the tester valve at the end of a test, normally, how many increments on the dial face should it move before stopping?
-
Question 7 of 38
7. Question
True or False: A good meter installation could have a resilient-seat gate valve directly upstream of the meter.
-
Question 8 of 38
8. Question
True or False: During a field test, a leaking downstream isolation valve will cause the meter under test to appear to register “high” in accuracy, especially at low flow rates.
-
Question 9 of 38
9. Question
True or False: All water meters are purely mechanical devices.
-
Question 10 of 38
10. Question
True or False: You should always bleed the residual line pressure from the meter assembly prior to removing any test plugs.
-
Question 11 of 38
11. Question
True or False: The way you read the meter will change depending on its units of measure.
-
Question 12 of 38
12. Question
How many tick marks are found on an ICE register?
-
Question 13 of 38
13. Question
How many odometer wheels are found on an ICE register?
-
Question 14 of 38
14. Question
If an OMNI meter or OMNI V2 needs recalibration, what is the most it can be adjusted?
-
Question 15 of 38
15. Question
Which of the following should you use to determine the flow rate for testing an OMNI meter? Check all that apply:
-
Question 16 of 38
16. Question
What is the highest acceptable static pressure for meter tests with the OMNI V2?
-
Question 17 of 38
17. Question
What is the maximum flow rate when using the OMNI V2?
-
Question 18 of 38
18. Question
What is the low flow capability of the OMNI V2?
-
Question 19 of 38
19. Question
Which of the following is true of the OMNI V2 tester tag? Check all that apply:
-
Question 20 of 38
20. Question
Which of the following checks should you perform if multiple tests on the same meter produce unusual results? Check all that apply:
-
Question 21 of 38
21. Question
When reading an OMNI register during a test, you should use which of the following modes?
-
Question 22 of 38
22. Question
How many times should you perform a test at each flow rate?
-
Question 23 of 38
23. Question
When testing non-OMNI meters, how should you determine the minimum amount of water for each test?
-
Question 24 of 38
24. Question
How many tests are typically required for a single meter across different flow rates?
-
Question 25 of 38
25. Question
If you encounter questionable accuracy results (and have already double-checked both meter strainers), which of the following methods should you try next?
-
Question 26 of 38
26. Question
How can you determine the crossover point of a non-OMNI compound meter?
-
Question 27 of 38
27. Question
What is the formula for testing a non-OMNI meter?
-
Question 28 of 38
28. Question
What is the correct procedure for preparing to test a meter with a bypass?
-
Question 29 of 38
29. Question
What are the purposes of meter testing? Check all that apply:
-
Question 30 of 38
30. Question
Why is it important to record the flow rates used during a test?
-
Question 31 of 38
31. Question
What should you do when having trouble reading a register?
-
Question 32 of 38
32. Question
What type of register is this?
-
Question 33 of 38
33. Question
What type of register is this?
-
Question 34 of 38
34. Question
Fill in the blank: You should not attempt a test when line pressure is lower than _____ PSI.
-
Question 35 of 38
35. Question
Which of the following should you return to Sensus when the OMNI V2 tester requires recalibration?
-
Question 36 of 38
36. Question
True or False: The AWWA M6 should be used to determine minimum, intermediate, and maximum test flow rates for different types and meter sizes.
-
Question 37 of 38
37. Question
What is the primary software to use when performing a meter test with the OMNI V2 tester?
-
Question 38 of 38
38. Question
When using the FieldLogic Communicator (Hockey Puck) to connect OMNI registers to the OMNI Flow Verification tool, you should _________.